DataMan 280 Changing 6.2 mm Lens to 16 mm Lens

This section provides a step-by-step process for changing the 6.2 mm lens to a 16 mm lens on the reader.

  1. Unscrew the four M2x12mm Phillips Pan head screws, then take off the metal cover from the reader.

  2. Remove the illumination module.

  3. Unscrew the two M2x5mm Phillips head screws, remove the 6.2 mm lens mount and the 6.2 mm lens.

  4. Attach the 16 mm lens mount and lens, and screw in the two M2x5mm Phillips head screws. Focus, if necessary.

  5. Attach the 16 mm lens illumination module.

  6. Attach the 16 mm lens front cover.

    Note: The rib in the front cover must be oriented to the top side.
    Note:

    Observing the tightening sequence below, tighten all four M2 x 12 mm Phillips Pan screws to 16 Ncm using a torque wrench.