This section provides a step-by-step process for changing the 6.2 mm lens to a 16 mm lens on the reader.
-
Unscrew the four M2x12mm Phillips Pan head screws, then take off the metal cover from the reader.
- Remove the illumination module.
-
Unscrew the two M2x5mm Phillips head screws, remove the 6.2 mm lens mount and the 6.2 mm lens.
- Attach the 16 mm lens mount and lens, and screw in the two M2x5mm Phillips head screws. Focus, if necessary.
- Attach the 16 mm lens illumination module.
-
Attach the 16 mm lens front cover.
Note: The rib in the front cover must be oriented to the top side.Note:Observing the tightening sequence below, tighten all four M2 x 12 mm Phillips Pan screws to 16 Ncm using a torque wrench.