In-Sight Ports
The following ports are used for In-Sight communications:
Port Number | Service |
---|---|
TCP 21 | FTP. For more information, see FTP Settings Dialog. |
TCP 23 | Telnet. For more information, see Dynamic Host Configuration Protocol (DHCP) Server. |
UDP 68 | DHCP (In-Sight vision system only) |
TCP 80 | HTTP |
TCP 502 | Modbus |
TCP 1069 | In-Sight Protocol |
UDP 1069 | In-Sight Discovery |
TCP 1070 | Machine Status data. For more information, see Sensor Status View. |
UDP 2222 | EtherNet/IP |
TCP 5753 | Audit Message Server |
UDP 45237 | Base SLMP messaging (GetCommunicationSetting). For more information, see Configure In-Sight Vision Systems for SLMP Scanner Communications. |
TCP 44818 | EtherNet/IP |
UDP 44818 | EtherNet/IP |
UDP 45237 | iQ Sensor Solution. For more information, see Communicate with a Mitsubishi Automation Controller via iQ Sensor Solution. |
TCP 50000 | DataChannel. For more information, see DataChannel Communications. |
UDP 61450 | CC-Link IE Field Basic: Cyclic request/response messages. For more information, see Communicating with a Mitsubishi Automation Controller on CC-Link IE Field Network Basic. |
UDP 61451 | CC-Link IE Field Basic: NodeSearch and IPAddressSet messages. For more information, see Communicating with a Mitsubishi Automation Controller on CC-Link IE Field Network Basic. |