In-Sight 9912 Hardware I/O Configurations

There are several options for connecting the In-Sight 9912 vision system's trigger, inputs, outputs, serial and power.

Breakout Cable Only

The vision system is connected to the Breakout cable (CCB-PWRIO- xx or CCB-PWRIO- xxR) and a Direct I/O connection has been established in the I/O Module Configuration dialog. In this configuration:

  • The Breakout cable supplies power to the vision system.
  • There is no connection to an I/O module.
  • Direct I/O is selected in the I/O Module Configuration dialog.
  • The vision system supports bi-directional high-speed outputs and general-purpose inputs for IN 2 / HSOUT 2 and IN 3 / HSOUT 3. These lines are configured as outputs by default.
Breakout Cable Pins Supported
TRIGGER
HSOUT 0
HSOUT 1
IN 1
IN 2 / HSOUT 2
IN 3 / HSOUT 3
COMMON IN
COMMON OUT
RS-232 TRANSMIT
RS-232 RECEIVE
+24VDC
GND

Breakout Cable and CIO-MICRO I/O Module

The vision system is connected to the Breakout cable (CCB-PWRIO- xx or CCB-PWRIO- xxR) and an Ethernet connection to a CIO-MICRO I/O module has been established in the I/O Module Configuration dialog. In this configuration:

  • The Breakout cable supplies power to the vision system.
  • CIO-MICRO is selected in the I/O Module Configuration dialog.
  • The vision system supports bi-directional high-speed outputs and general-purpose inputs for IN 2 / HSOUT 2 and IN 3 / HSOUT 3. These lines are configured as outputs by default.
  • The CIO-MICRO I/O module's TRIGGER+, TRIGGER-, HSOUT 0, HSOUT 1 and HS COMMON terminals are not supported. Do not connect wire leads from remote devices to these terminals.
  • The RS-232 TRANSMIT and RS-232 RECEIVE pins on the Breakout cable are disabled. Use the I/O module's RS-232 OUT port (DB9) to connect to a serial device.
Breakout Cable Pins Supported
TRIGGER
HSOUT 0
HSOUT 1
IN 1
IN 2 / HSOUT 2
IN 3 / HSOUT 3
COMMON IN
COMMON OUT
RS-232 TRANSMIT Not Supported
RS-232 RECEIVE Not Supported
+24VDC
GND
CIO-MICRO I/O Module Terminals Supported
+24VDC Not Supported
-24VDC Not Supported
TRIGGER+ Not Supported
TRIGGER- Not Supported
HSOUT 1 Not Supported
HSOUT 0 Not Supported
HS COMMON Not Supported
INPUT 7
INPUT 6
INPUT 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1
INPUT 0
IN COMMON
OUT 7
OUT 6
OUT 5
OUT 4
OUT 3
OUT 2
OUT 1
OUT 0
OUT COMMON
RS-232 OUT

I/O Module Cable and CIO-MICRO I/O Module

The vision system is connected to the I/O Module cable (CCB-PWRIO-MOD-xx) and an Ethernet connection to a CIO-MICRO I/O module has been established in the I/O Module Configuration dialog. In this configuration:

  • The I/O module cable supplies power to the vision system.
  • CIO-MICRO is selected in the I/O Module Configuration dialog.
  • The vision system's IN 1, IN 2, IN 3, HSOUT 2 and HSOUT 3 lines are displayed in the Discrete I/O Settings dialog but are not supported. These lines are only supported when the vision system is connected to the Breakout cable.
  • TRIGGER+, TRIGGER-, HSOUT 0, HSOUT 1 and HS COMMON are connected via the CIO-MICRO I/O module terminals.
  • Illumination accessories attached to the vision system LIGHT connector are not supported. If these illumination accessories are attached, the Breakout cable must be used to supply power to the vision system and a connection to the I/O module established via Ethernet only.
CIO-MICRO I/O Module Terminals Supported
+24VDC
-24VDC
TRIGGER+

TRIGGER-

HSOUT 0
HSOUT 1
HS COMMON
INPUT 7
INPUT 6
INPUT 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1
INPUT 0
IN COMMON
OUT 7
OUT 6
OUT 5
OUT 4
OUT 3
OUT 2
OUT 1
OUT 0
OUT COMMON
RS-232 OUT

I/O Module Cable and CIO-1400 I/O Module

The vision system is connected to the I/O Module cable (CCB-PWRIO-MOD-xx) and a connection to a CIO-1400 I/O module has been established in the I/O Module Configuration dialog. In this configuration:

  • The I/O module cable supplies power to the vision system.
  • CIO-1400 is selected in the I/O Module Configuration dialog.
  • The vision system's IN 1, IN 2, IN 3, HSOUT 2 and HSOUT 3 lines are not supported.
CIO-1400 I/O Module Supported
+24VDC
-24VDC
TRIGGER-
TRIGGER+
INPUT 7
INPUT 6
INPUT 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1
INPUT 0
IN COMMON
OUT 7
OUT 6
OUT 5
OUT 4
OUT 3
OUT 2
OUT 1
OUT 0
HSOUT 1
HSOUT 0
OUT COMMON
RS-232 OUT