Configuring the CC-Link Settings Tab
The CC-Link Settings tab is used to configure the In-Sight CIO-Micro-CC I/O module for communication on the CC-Link network.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Defines whether or not the CC-Link interface on the In-Sight CIO-Micro-CC I/O module is enabled or disabled. By default, the Enable checkbox is checked, and the CC-Link interface on the In-Sight CIO-Micro-CC I/O module is enabled. Uncheck the Enable checkbox to diagnose and debug your CC-Link connection, should the need arise.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Defines the CC-Link specification compatibility, V1 or V2. By default, V1 is selected.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Defines the CC-Link baud rate of the CC-Link network, 10M, 5M, 2.5M, 625k, 156k. By default, 10M is selected.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Defines the station number of the CC-Link slave, from 1 to 64. By default, 1 is selected.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Defines the number of stations that the In-Sight CIO-Micro-CC I/O module occupies on the CC-Link network, from 1 to 4. By default, 1 is selected.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Defines the number of extension cycles that the In-Sight CIO-Micro-CC I/O module utilizes on the CC-Link network, 1X (Disabled), 2X, 4X, or 8X. By default, 1X (Disabled) is selected.
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Displays the number of bits and words available in the input bit and word buffers, respectively.
To determine the number of bits available in the input buffer:
- When the Version parameter is set to V1: 32 x (Number of Stations)-16
- When the Version parameter is set to V2, and the Extension Cycles parameter is set to 1X (Disabled): 32 x (Number of Stations)-16
- When the Version parameter is set to V2 and the Extension Cycles parameter is enabled: 32 x (Number of Stations) x (Extension Cycles) - 16 x (Extension Cycles) - 16
To determine the number of words available in the input buffer:
- When the Version parameter is set to V1: 4 x (Number of Stations)
- When the Version parameter is set to V2, and the Extension Cycles parameter is set to 1X (Disabled): 4 x (Number of Stations)
- When the Version parameter is set to V2 and the Extension Cycles parameter is enabled: 4 x (Number of Stations) x (Extension Cycles)
![Closed](../../Skins/Default/Stylesheets/Images/transparent.gif)
Displays the number of bits and words available in the output bit and word buffers, respectively.
To determine the number of bits available in the output buffer:
- When the Version parameter is set to V1: 32 x (Number of Stations)-16
- When the Version parameter is set to V2, and the Extension Cycles parameter is set to 1X (Disabled): 32 x (Number of Stations)-16
- When the Version parameter is set to V2 and the Extension Cycles parameter is enabled: 32 x (Number of Stations) x (Extension Cycles) - 16 x (Extension Cycles) - 16
To determine the number of words available in the output buffer:
- When the Version parameter is set to V1: 4 x (Number of Stations)
- When the Version parameter is set to V2, and the Extension Cycles parameter is set to 1X (Disabled): 4 x (Number of Stations)
- When the Version parameter is set to V2 and the Extension Cycles parameter is enabled: 4 x (Number of Stations) x (Extension Cycles)