GetDiscreteOutput
Returns information that is configured in the Discrete I/O Settings dialog. For more information, see Configure Discrete I/O Lines.
GetDiscreteOutput Inputs
Syntax: EV GetDiscreteOutput()
GetDiscreteOutput Outputs
Returns a status code, followed by the number of characters (in bytes) for the results, then the results in XML format. The status codes are:
Status Codes | Description |
---|---|
1 | The command was executed successfully. |
0 | Unrecognized command. |
-2 | The command could not be executed. |
-6 | User does not have Full
Access to execute the command. |
GetDiscreteOutput Example
To retrieve the information configured in the Discrete I/O Settings dialog, issue the following command: EV GetDiscreteOutput()
The In-Sight sensor responds with a status code (1), followed by the number of characters, in bytes (637). Finally, the information configured in the Discrete I/O Settings dialog is returned.