SetDeEnergizeOutputs
Configures the De-Energize Outputs While Offline setting found in the Discrete I/O Settings dialog.
SetDeEnergizeOutputs Inputs
Syntax: EV SetDeEnergizeOutputs(DeEnergizeOutputs,WriteProcSet)
Parameter | Description |
---|---|
DeEnergizeOutputs |
|
WriteProcSet |
|
SetDeEnergizeOutputs Outputs
Returns a status code, followed by the number of characters (in bytes) for the results, then the results in XML format. The status codes are:
Status Codes | Description |
---|---|
1 | The command was executed successfully. |
0 | Unrecognized command. |
-2 | The command could not be executed. |
-6 | User does not have Full
Access to execute the command. |
SetDeEnergizeOutputs Example
To configure the sensor to de-energize outputs when placed Offline, issue the following command: EV SetDeEnergizeOutputs(1,1)