In-Sight 8000 Series I/O Lines
Note:
- HS OUT 0 and HS OUT 1 are built-in high-speed outputs, direct from the vision system.
- The vision system supports the Strobe signal type for the HSOUT 1 line.
- If using a strobe with the In-Sight 8405 vision system, a minimum Exposure value of 72ms is recommended for a full frame image capture, to ensure that all pixel rows are exposed when the strobe is pulsed. For more information, see In-Sight 8405 Rolling Shutter Operation.
Direct I/O
Output | Name |
---|---|
0 | HSOUT 0 |
1 | HSOUT 1 |
4 | Green LED |
5 | Red LED |
CIO-MICRO
Note:
- The CIO-MICRO I/O module supports In-Sight 8000 series vision systems with firmware version 5.3.0 and higher.
- The In-Sight 8500 series vision system must be connected to a Class 0, 3 or 4 PoE power source, rated for at least 12.95 Watts. The CIO-MICRO I/O module is a Class 2 PoE device and therefore cannot be used to supply power to the In-Sight 8500 series vision system via the I/O module's PoE port. Instead, connect the vision system's Ethernet cable to a Class 0, 3 or 4 PoE power source and establish a connection to I/O module over the local area network using In-Sight Explorer.
Input | Name |
---|---|
0 | Line 0 |
1 | Line 1 |
2 | Line 2 |
3 | Line 3 |
4 | Line 4 |
5 | Line 5 |
6 | Line 6 |
7 | Line 7 |
Output | Name |
0 | Line 0 |
1 | Line 1 |
2 | Line 2 |
3 | Line 3 |
4 | Line 4 |
5 | Line 5 |
6 | Line 6 |
7 | Line 7 |
8 | HSOUT 0 |
9 | HSOUT 1 |
10 | Green LED |
11 | Red LED |