In-Sight 8000 Series I/O Lines

Note:
  • HS OUT 0 and HS OUT 1 are built-in high-speed outputs, direct from the vision system.
  • The vision system supports the Strobe signal type for the HSOUT 1 line.
  • If using a strobe with the In-Sight 8405 vision system, a minimum Exposure value of 72ms is recommended for a full frame image capture, to ensure that all pixel rows are exposed when the strobe is pulsed. For more information, see In-Sight 8405 Rolling Shutter Operation.

Direct I/O

Output Name
0 HSOUT 0
1 HSOUT 1
4 Green LED
5 Red LED

CIO-MICRO

Note:
  • The CIO-MICRO I/O module supports In-Sight 8000 series vision systems with firmware version 5.3.0 and higher.
  • The In-Sight 8500 series vision system must be connected to a Class 0, 3 or 4 PoE power source, rated for at least 12.95 Watts. The CIO-MICRO I/O module is a Class 2 PoE device and therefore cannot be used to supply power to the In-Sight 8500 series vision system via the I/O module's PoE port. Instead, connect the vision system's Ethernet cable to a Class 0, 3 or 4 PoE power source and establish a connection to I/O module over the local area network using In-Sight Explorer.
Input Name
0 Line 0
1 Line 1
2 Line 2
3 Line 3
4 Line 4
5 Line 5
6 Line 6
7 Line 7
Output Name
0 Line 0
1 Line 1
2 Line 2
3 Line 3
4 Line 4
5 Line 5
6 Line 6
7 Line 7
8 HSOUT 0
9 HSOUT 1
10 Green LED
11 Red LED