In-Sight 9902L Hardware I/O Configurations

There are several options for connecting the In-Sight 9902L vision system's trigger, inputs, outputs, serial and power.

Breakout Cable Only

The vision system is connected to the Breakout cable (CCB-PWRIO- xx or CCB-PWRIO- xxR) and a Direct I/O connection has been established in the I/O Module Configuration dialog. In this configuration:

  • The Breakout cable supplies power to the vision system.
  • There is no connection to an I/O module.
  • Direct I/O is selected in the I/O Module Configuration dialog.
Breakout Cable Pins Supported
TRIGGER
HSOUT 0
HSOUT 1
IN 1
ENCODER A INPUT
ENCODER B INPUT
COMMON IN
COMMON OUT
RS-232 TRANSMIT
RS-232 RECEIVE
+24VDC
GND

Breakout Cable and CIO-MICRO I/O Module

The vision system is connected to the Breakout cable (CCB-PWRIO- xx or CCB-PWRIO- xxR) and an Ethernet connection to a CIO-MICRO I/O module has been established in the I/O Module Configuration dialog. In this configuration:

  • The Breakout cable supplies power to the vision system.
  • CIO-MICRO is selected in the I/O Module Configuration dialog.
  • The CIO-MICRO I/O module's TRIGGER+, TRIGGER-, HSOUT 0, HSOUT 1 and HS COMMON terminals are not supported. Do not connect wire leads from remote devices to these terminals.
  • The RS-232 TRANSMIT and RS-232 RECEIVE pins on the Breakout cable are disabled. Use the I/O module's RS-232 OUT port (DB9) to connect to a serial device.
Breakout Cable Pins Supported
TRIGGER
HSOUT 0
HSOUT 1
IN 1
ENCODER A INPUT
ENCODER B INPUT
COMMON IN
COMMON OUT
RS-232 TRANSMIT Not Supported
RS-232 RECEIVE Not Supported
+24VDC
GND
CIO-MICRO I/O Module Terminals Supported
+24VDC Not Supported
-24VDC Not Supported
TRIGGER+ Not Supported
TRIGGER- Not Supported
HSOUT 1 Not Supported
HSOUT 0 Not Supported
HS COMMON Not Supported
INPUT 7
INPUT 6
INPUT 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1
INPUT 0
IN COMMON
OUT 7
OUT 6
OUT 5
OUT 4
OUT 3
OUT 2
OUT 1
OUT 0
OUT COMMON
RS-232 OUT

I/O Module Cable and CIO-MICRO I/O Module

The vision system is connected to the I/O Module cable (CCB-PWRIO-MOD-xx) and an Ethernet connection to a CIO-MICRO I/O module has been established in the I/O Module Configuration dialog. In this configuration:

  • The I/O module cable supplies power to the vision system.
  • CIO-MICRO is selected in the I/O Module Configuration dialog.
  • The vision system's ENCODER A INPUT, ENCODER B INPUT and IN 1 lines are not supported. These lines are only supported when the vision system is connected to the Breakout cable.
  • TRIGGER+, TRIGGER-, HSOUT 0, HSOUT 1 and HS COMMON are connected via the CIO-MICRO I/O module terminals.
CIO-MICRO I/O Module Terminals Supported
+24VDC
-24VDC
TRIGGER+

TRIGGER-

HSOUT 0
HSOUT 1
HS COMMON
INPUT 7
INPUT 6
INPUT 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1
INPUT 0
IN COMMON
OUT 7
OUT 6
OUT 5
OUT 4
OUT 3
OUT 2
OUT 1
OUT 0
OUT COMMON
RS-232 OUT

I/O Module Cable and CIO-1400 I/O Module

The vision system is connected to the I/O Module cable (CCB-PWRIO-MOD-xx) and a connection to a CIO-1400 I/O module has been established in the I/O Module Configuration dialog. In this configuration:

  • The I/O module cable supplies power to the vision system.
  • CIO-1400 is selected in the I/O Module Configuration dialog.
  • The vision system's ENCODER A INPUT, ENCODER B INPUT and IN 1 lines are not supported. These lines are only supported when the vision system is connected to the Breakout cable.
CIO-1400 I/O Module Supported
+24VDC
-24VDC
TRIGGER-
TRIGGER+
INPUT 7
INPUT 6
INPUT 5
INPUT 4
INPUT 3
INPUT 2
INPUT 1
INPUT 0
IN COMMON
OUT 7
OUT 6
OUT 5
OUT 4
OUT 3
OUT 2
OUT 1
OUT 0
HSOUT 1
HSOUT 0
OUT COMMON
RS-232 OUT