EtherNet/IP Input Assembly - Instance 14

Note: For detailed descriptions of the signals, see Industrial Communications Signals.
Instance

Byte

Bit 7

Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
14

0

Online

Paused

Reserved

Acquisition Error

Reserved

Trigger Acknowledge

Trigger Ready

1

Error

Command Failed

Command Completed

Command Executing

Results Valid

Results Buffer Overrun

Inspection Completed

System Ready

2

Reserved

Results Passed

Exposure Complete

Reserved

Set User Data Acknowledge

3

External Event Acknowledge 7

External Event Acknowledge 6

External Event Acknowledge 5

External Event Acknowledge 4

External Event Acknowledge 3

External Event Acknowledge 2

External Event Acknowledge 1

External Event Acknowledge 0

4 .. 5

Error ID (16-bit integer)

6 .. 7

Command Result Code (16-bit integer)

8 .. 9

Reserved (16-bit integer)

10 .. 11

Acquisition ID (16-bit integer)

12 .. 13

Inspection ID (16-bit integer)

14 .. 15

Inspection Result Code (16-bit integer)

16 .. 499 Inspection Results 0 - 483