EtherNet/IP Output Assembly - Instance 23

Note: For detailed descriptions of the signals, see Industrial Communications Signals.
Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
23

0

Set Paused

Reserved

Execute Command

Inspection Results Acknowledge

Buffer Results Enable

Trigger

Trigger Enable

1

Reserved

2

Reserved

Clear Exposure Complete

Clear Error

Reserved

Set User Data

3

External Event 7

External Event 6

External Event 5

External Event 4

External Event 3

External Event 2

External Event 1

External Event 0

4 .. 5

Command ID

6 .. 7

Reserved

8 .. 495

User Data 0 - 487