In-Sight D900 Series I/O Lines

Number of Input and Output Lines

In-Sight Vision System Direct Inputs Direct Outputs
In-Sight D900 Series

1 acquisition trigger input

Up to 3 general-purpose inputs

Up to 4 high-speed outputs

2 user-configurable LEDs (1 green or red, 1 red)

Input and Output Lines

In Out Direction Name
0   Fixed Input TRIGGER
1   Fixed Input IN 1
  0 Fixed Output HSOUT 0
  1 Fixed Output HSOUT 1
2 2 Input or Output IN 2/HSOUT 2
3 3 Input or Output IN 3/HSOUT 3
  4 Fixed Output Pass/Fail LED
  5 Fixed Output Error LED
Note:
  • TRIGGER is reserved for acquisition trigger input and cannot be configured.
  • The In-Sight D900 series vision system supports bi-directional high-speed outputs and general-purpose inputs for HSOUT 2 / IN 2 and HSOUT 3 / IN 3. These lines are configured as outputs by default.