EtherNet/IP Input Assembly - Instance 11

Note: For detailed descriptions of the signals, see Industrial Communications Signals.
Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
11 0 Online Paused Reserved System Ready
1 Error Command Failed Command Completed Command Executing Reserved
2..3 Reserved
4..5 Command Result Code
6..7 Error ID
8..11 External Event Acknowledge 0 - 31
12..15 Reserved
16 Results Buffer Overrun 0 Inspection Passed 0 Results Valid 0 Inspection Completed 0 Exposure Complete 0 Acquisition Error 0 Trigger Acknowledge Camera 0 Trigger Ready Camera 0
17 Reserved Set User Data Acknowledge 0
18..19 Acquisition ID 0
20..21 Inspection Image ID 0
22..23 Inspection Result Code 0
24 Results Buffer Overrun 1 Inspection Passed 1 Results Valid 1 Inspection Completed 1 Exposure Complete 1 Acquisition Error 1 Trigger Acknowledge Camera 1 Trigger Ready Camera 1
25 Reserved Set User Data Acknowledge 1
26..27 Acquisition ID 1
28..29 Inspection Image ID 1
30..31 Inspection Result Code 1
32 Results Buffer Overrun 2 Inspection Passed 2 Results Valid 2 Inspection Completed 2 Exposure Complete 2 Acquisition Error 2 Trigger Acknowledge Camera 2 Trigger Ready Camera 2
33 Reserved Set User Data Acknowledge 2
34..35 Acquisition ID 2
36..37 Inspection Image ID 2
38..39 Inspection Result Code 2
40 Results Buffer Overrun 3 Inspection Passed 3 Results Valid 3 Inspection Completed 3 Exposure Complete 3 Acquisition Error 3 Trigger Acknowledge Camera 3 Trigger Ready Camera 3
41 Reserved Set User Data Acknowledge 3
42..43 Acquisition ID 3
44..45 Inspection Image ID 3
46..47 Inspection Result Code 3
48..499 Inspection Results 0...451