12/17/2024

Question

What is supported on ENET 0 and ENET 1?

Answer

ENET0: Connection to In-Sight Vision Suite, Web HMI, TCP/IP, OPC/UA, FTP, and FFP (Ethernet/IP, Profinet, SLMP, etc.)

ENET1: Connection to In-Sight Vision Suite, Web HMI, TCP/IP, OPC/UA, FTP

Only one connection to In-Sight Vision Suite at a time is supported. You cannot connect to In-Sight Vision Suite on both ethernet ports simultaneously.

Only one FFP (Factory Floor Protocol) can be used at once across both ethernet connections. FFPs include Profinet, EtherNet/IP, and SLMP.

Recommended to use ENET0 for FFP as it is required for both Profinet, Ethernet/IP, and SLMP

For high-speed applications with FFP, it is recommended to connect to In-Sight Vision Suite with ENET1

The Web HMI CAN be connected to both ethernet ports simultaneously.

Example Valid Configurations:

  • ENET0 = Profinet; ENET1 = In-Sight Vision Suite, FTP;
  • ENET0 = In-Sight Vision Suite; ENET1 = TCP/IP, FTP;
  • ENET0 = Profinet, FTP; ENET1 = OPC/UA, In-Sight Vision Suite;