Changes from In-Sight Explorer 6.5.1 firmware 20 to firmware 22 *Updated 4-Nov-2024*
- Fixed a case where WebHMI connection was broken
New Features
In-Sight Explorer 6.5.1 introduces the following new feature:
- ValidateIDData: updated GS1 data validation by supporting new application identifiers (AIs) to August 2024 version. This includes AIs 716, 7041, 7250-7259, 4330-4333, 7241, 7242, and 8030. Further enhanced AIs 8013 and 8014.
Bug Fixes
In addition to the new feature, several bugs were fixed in this release including:
- Audit messaging: WebHMI user and host source are now correctly logged when modifying the EditCompositeRegion function.
- Audit messaging: Unsuccessful login attempts are now logged.
- Fixed a firmware memory leak that occurs when opening and closing WebHMI connections.
- Resolved a 9902L issue where connections could be dropped due to noise interference.
- Discrete outputs: Fixed a condition where output pulse widths were occasionally shorter than expected. This was observed on fast-triggering applications, or when multiple output signals occurred simultaneously.
- Fixed a fatal condition that could occur during the bootup process of an In-Sight 8500 series vision system.
- ReadIDMax omni-postal (PLANET): improved decoding for 14-digit Postnet codes, resolving certain no-read conditions.
- Cognex Network Server documentation: added instructions on how to set up a remote datastore for Audit Logging. For more information, see the Cognex Network Server documentation.
Compatible firmware
In-Sight Explorer 6.5.1 includes firmware versions for the following models:
(1) In-Sight firmware 6.05.01
- In-Sight 7000 Gen2 (7500+) series vision systems
- In-Sight 8000 series vision systems
- In-Sight 9000 Series Vision System
- In-Sight Advantage Engine
(2) In-Sight firmware 5.09.02
- In-Sight 5705M and 5705C vision systems
(3) In-Sight firmware 4.10.05 PR1
- In-Sight Micro 1000 series vision systems
- In-Sight 5000 series vision systems (except In-Sight 5705M and 5705C vision systems)
- In-Sight 7000 Gen1 series vision systems (except In-Sight 7000 Gen2 (7500+) series vision systems)
Note
If you are using TruCheck / standards-based grading (SBG), please use the latest In-Sight Explorer 6.3.x.
Windows system requirements
In-Sight Explorer 6.5.1 supports the following Windows operating systems:
- Microsoft Windows 10 Professional (64-bit)
- Microsoft Windows Server 2016
If you are using Windows 7 (64-bit), please use In-Sight Explorer 5.9.2.
Please find the full list of updates and bug fixes after installation from the help menu in In-Sight Explorer or in the program files directory (e.g. C:\Program Files (x86)\Cognex\In-Sight\In-Sight Explorer 6.5.1\Documentation\Release Notes).