Content Summary
The DM8072V Barcode verifier firmware, released February 2020, enhances functionality with version 5.7.7 SR4. To install, unzip and run the executable; the firmware file is saved automatically. Key improvements include fixing lockups on trigger, enhancing error checking on TEI data fields, and updating GS1 Table 7 rules. Grading issues with MR lighting and EDIFACT data are resolved, and non-numeric check digits are better checked. This release targets DM8072V and DM8072V-HD, compatible with Setup Tool 5.7.7 SR3.
Firmware for DM8072V Barcode verifier released February 2020.
- Unzip the file.
- Run the executable.
- The executable will automatically save the firmware file into the DataMan Setup Tool firmware folder.
Release Notes:
DataMan® 5.7.7 SR4 Release Notes
Copyright (C) 2020 Cognex Corporation
Version 5.7.7 SR4
All Rights Reserved
The 5.7.7 SR4 improves functionality of the DM8072V Verifier
- Fixed lockups on trigger in certain circumstances
- Removed grading on MR when “/90” lighting is used with ISO/IEC 29158 grading
- Increased strictness of error checking on TEI data fields to reject dot and space characters
- Fixed issue with EDIFACT data that includes a question mark character
- Fixed checking of non-numeric check digits
- Updated application specification rules for GS1 Table 7
- Improved stability of results certain Data Matrix symbols
This release is for DM8072V and DM8072V-HD and is intended to be used with Setup Tool 5.7.7 SR3