Content Summary
The DataMan 25.4.1 software supports all active DataMan products, including a common Setup Tool. It delivers new firmware for all active DataMan products.
The DataMan 25.4.1 software supports all active DataMan products, including a common Setup Tool. It delivers new firmware for all active DataMan products. The DataMan 25.4.1 release further refines and supplements the functionality of DataMan 25.3.2 with general enhancements, bugfixes, and the latest documentation.
General updates applicable to DataMan fixed-mount platforms 280/80, 380/580, and 290/390
- Added TCP/IP server and client image offload methods
- Added Airport Baggage Handling (ABH) redundancy, including trigger continuity and health logging of PLCs and PEs
- Added option for delays based on fixed or measured belt speed
General updates applicable to DataMan platforms 280/80, 380/580, 290/390, and 8700
- You can disable push notifications to DMCC console
- Optional SFTP server fingerprint check
- Bugfixes
- FFP soft event is now enabled after the reader is ready
- Fixed an issue with preserving gateway in case the PLC is assigned IP settings
- Fixed an issue with motion detection continuously triggering in darkness
- Fixed an FFP bug where sending SCRIPT.LOAD DMCC with additional data was not working
- Fixed an issue where mDNS was not working after factory reset
- Fixed an issue where transferring characters in HID mode with Alt Key Combo language setting stopped working after pressing the CapsLock button
Verifier improvements applicable to DataMan verifier platforms 470 and 8072
- Auto-batch improvements
- UEC now reports to one decimal point
- Updated AI 22 to new definition
- Added AI 715 and AI 716 support
- Added checking for X-dimension range to HIBCC and MIL STD 130 application standards
- Bugfixes
- Fixed AIs 710 through 714 to allow alphanumeric data
- Fixed ISO 15434 data parsing to check for missing RS and EOT control characters at the end
- Fixed a bug in Data Matrix where EDIFACT encoding included any NULL codewords
- Fixed GS1 data parsing bug for Date/Time stamps that contain optional hours and minutes
Firmware Version 7.0.2 (DataMan 290 Platform) and 7.1.2 (DataMan 390 Platform)
- You can enable TruCheck Standards-Based Grading (SBG) in the WebUI and have the Runtime view display ISO parameter results and download reports for the most recent trigger
- Separate image viewer added with support for legacy browsers
- Re-enabled GS1 Composite decoder
- Miscellaneous No Read Feedback improvements
Firmware Version 6.4.2 SR4 (DataMan 580 Platform) and 6.5.2 SR4 (DataMan 380 Platform)
- ROI support for DataMan 3808, 3812, 3816, and 5809
- Miscellaneous No Read Feedback improvements
Firmware Version 6.3.9 (DataMan 80 and 280 Platforms)
- Separate image viewer added with support for legacy browsers
- Added WebUI support for the DataMan 80 and 280 platforms, with limited support for High-Power Integrated Torch, DataMan 280 EtherCAT, and DataMan 80-USB
- Re-enabled GS1 Composite decoder
- Added option to disable power issue signaling on the DataMan 80
- Bugfixes
- Fixed an issue with the Modular Lens Setup parameter
- Fixed an issue with the DataMan 282 torch light configurations being overwritten when booted through a PoE source
Firmware Version 6.2.9 SR2 (DataMan 8700 Platform)
- Separate image viewer added with support for legacy browsers
- Bugfixes
- Fixed the formatting of [105] error DMCC response when the reader is offline
Firmware Version 6.1.16 SR4 (DataMan 370 and 470 Platforms)
- Bugfixes
- Fixed an issue where No Read images were not saved through FTP
- Fixed LED overheating issue
- Fixed an issue where an SFTP server disconnect interrupted DataMan PROFINET reader communication
- Fixed an issue where SFTP stopped working until rebooted or the toggle Enable Idle Timeout was enabled
Firmware Version 5.7.10 SR4 (DataMan 8072V Platform)
- Added support for ISO/IEC 15415:2024 and ISO/IEC 29158:2025
WebUI updates
- Added WebUI support for the DataMan 80 and 280 platforms, with limited support for High-Power Integrated Torch, DataMan 280 EtherCAT, and DataMan 80-USB
- Result output over Telnet can now be suppressed
- SFTP server fingerprint support added
- Support for image offload through TCP client or Local TCP Server
- Support for transferring SVG overlay graphics over FTP
- Support for adjusting reader FOV
- Support for sending Verification reports over FTP
- Support for training the code
- Enhancements
- Exit Runtime screen now returns to previous screen
- Image transfer optimization
- Collapsing sub-steps menu now persists
- Improved handling of wireless devices when the reader goes offline
- Code quality results are now supported for multicode reads
- Bugfixes
- Fixed an issue with trigger requests being out or order
- Fixed an issue with the Home page not loading
General Notes for DataMan 25.4.1
- Updated GS1 data validation with digital link support
- Added new TruCheck Grade Data Formatting tokens
- Image FTP Transfer Server Address Control now adapts visibility and editability based on the selected Server Type
- The TruCheck™ Calibration date now shows the correct 30-day notice
- No Read Feedback now has a string representation as "The barcode appears to be damaged"
Firmware installed with DataMan 25.4.1 Software
- DM50_DM60_DM70_DM150_DM260_v5.7.3_sr3.bin.gz
- DM80_DM280_v6.3.9.bin.gz
- DM290_v7.0.2.cogfw
- DM300_v5.5.0_sr4.bin.gz
- DM300_v5.7.3_sr3.bin.gz
- DM390_v7.1.2.cogfw
- DM370_DM470_v6.1.16_sr4.bin.gz
- DM380_v6.5.2_sr4.bin.gz
- DM580_v6.4.2_sr4.bin.gz
- DM8050_v5.4.5.bin.gz
- DM8070_v5.7.10_sr4.bin.gz
- DM8700_v6.2.9_sr2.bin.gz