Details
Issue Description
The issue with In-Sight Vision Suite (ISVS) on a Windows 10 Pro system where the application fails to launch when logged in as an Administrator, even though the software was installed using administrative privileges.
Symptoms Observed
- ISVS does not start under the administrator account.
- No UI is displayed when launching Cognex.Explorer.exe.
- Windows Event Viewer logs show an application crash related to:
- Application: Cognex.Explorer.exe
- Fault Module: KERNELBASE.dll
- Exception Code: e0434352
- ISVS may temporarily work after creating a new Windows user profile, but the issue reoccurs after a few days.
Resolution
- Log in to Windows using an account with administrative privileges.
- Uninstall all Cognex-related software from Programs and Features.
- Navigate to the following directory:
C:\Users\[User_Profile]\AppData\Local\ - Delete the folder:
Cognex_Corporation - Reboot the PC.
- Reinstall In-Sight Vision Suite (ISVS).
- Launch ISVS and verify that it opens correctly under the administrator account.