How to Enable SBG on the DataMan 290/ DataMan 390

How to enable SBG on the DataMan 290/DataMan 390.

16/02/2026

Details

  1. Start setup tool.

    How to enable SBG on the DM290 and DM390 80_image-1
  2. Connect the reader, navigate to the operation interface, select Verification, and the SBG function will be enabled immediately.

    How to enable SBG on the DM290 and DM390_image-2
  3. Enter -image view-select TruCheck Window.

    How to enable SBG on the DM290 and DM390_image-3
  4. Access the TruCheck verification interface. When the message "The unit is not calibrated" pops up, it can be ignored. This is because we do not require a strict ISO - compliant grade, and the SBG function is mainly used to screen out damaged codes for in - factory code quality control.

    How to enable SBG on the DM290 and DM390_image-4
  5. The setting of SBG is same as standard verifier.

    How to enable SBG on the DM290 and DM390_image-5

Important Note: If you want to restore the reader to the code - only reading mode, you must disable the Verification function, as it will compromise the decoding speed.