Details
Procedure:
- Make ‘Set Offline’ bit (Acquisition Control Bit 7) ‘High’.
- Enter ‘Program Number’ (Value) in ‘Command Control input’.
- Make ‘Execute Command’ bit (Inspection Control-Bit 3) ‘High’.
- Confirm Command Completed & Failed feedback (Inspection Status-Bit 5&6).
- Make ‘Execute Command’ bit (Inspection Control-Bit 3) ‘Low’.
- Make “Set Offline” Bit (Acquisition Control Bit 7) “Low”.
- Confirm Program number in “command Control Output”.