Configuring the Format Input Bit/Word Data Tabs and the Format Output Bit/Word Data Tabs (CC-Link IE Field Basic)

The Format Input Bit Data, Format Input Word Data, Format Output Bit Data, and Format Output Word Data tabs are used to define the tool or job data that will be transferred to and from the Mitsubishi PLC/MC and the In-Sight vision system over the CC-Link IE Field Basic protocol.

Note:
  • In this topic, an input is an input into the In-Sight vision system, and an output is an output from the vision system.
  • For more information, see the In-Sight® Explorer Help file.
Tab PLC Memory Space Starting Offset Size Limitation
(When Occupying 1 Station)
Data Type
Format Input Bit Data RY 32 32 bits
Format Input Word Data RWw 2 30 16-bit words
Format Output Bit Data RX 32 32 bits
Format Output Word Data RWr 5 27 16-bit words