GetDiscreteOutput

Returns information that is configured in the Discrete I/O Settings dialog. For more information, see Configure Discrete I/O Lines.

GetDiscreteOutput Inputs

Syntax: EV GetDiscreteOutput()

GetDiscreteOutput Outputs

Returns a status code, followed by the number of characters (in bytes) for the results, then the results in XML format. The status codes are:

Status Codes Description
1 The command was executed successfully.
0 Unrecognized command.
-2 The command could not be executed.
-6 User does not have Full Access to execute the command. For more information, see User Access Settings Dialog.

GetDiscreteOutput Example

To retrieve the information configured in the Discrete I/O Settings dialog, issue the following command: EV GetDiscreteOutput()

Note: Count, in the first XML tag, represents the number of discrete outputs. Each discrete output is assigned a Line ID (zero-based.)

The In-Sight sensor responds with a status code (1), followed by the number of characters, in bytes (637). Finally, the information configured in the Discrete I/O Settings dialog is returned.