Machine Status Port

The In-Sight Machine Status Port is a TCP/IP connection at port 1070, which gives a remote client access to Machine Status data for an In-Sight system without requiring user name and password login. The GetMSBuffer command can be used without the EV prefix when executed through this read-only port. The connection will time out after 15 seconds; up to 5 simultaneous connections can be made to port 1070. For more information, see GetMSBuffer.