In-Sight Ports

The following ports are used for In-Sight communications:

Port Number Service
TCP 21 FTP. For more information, see FTP Settings Dialog.
TCP 23 Telnet. For more information, see Dynamic Host Configuration Protocol (DHCP) Server.
UDP 68 DHCP (In-Sight vision system only)
TCP 502 Modbus
TCP 1069 In-Sight Protocol
UDP 1069 In-Sight Discovery
TCP 1070 Machine Status data. For more information, see Sensor Status View.
UDP 2222 EtherNet/IP
TCP 5753 Audit Message Server
TCP 8087 Web HMI HTTP (Default)
TCP 8443 Web HMI HTTPS (Default)
UDP 45237 Base SLMP messaging (GetCommunicationSetting). For more information, see Configure In-Sight Vision Systems for SLMP Scanner Communications.
TCP 44818 EtherNet/IP
UDP 44818 EtherNet/IP
UDP 45237 iQ Sensor Solution. For more information, see Communicate with a Mitsubishi Automation Controller via iQ Sensor Solution.
TCP 50000 DataChannel. For more information, see DataChannel Communications.
UDP 61450 CC-Link IE Field Basic: Cyclic request/response messages. For more information, see Communicate with a Mitsubishi Automation Controller on CC-Link IE Field Network Basic.
UDP 61451 CC-Link IE Field Basic: NodeSearch and IPAddressSet messages. For more information, see Communicate with a Mitsubishi Automation Controller on CC-Link IE Field Network Basic.