Using the Pattern and Patterns (1-10) Location Tools Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

In-Sight 2000 Series 1XX Vision Sensors (110, 120, 130)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Accept_Threshold I X In
Accuracy I   In
Description S X In
Execution_Time FP X  
Extenal_Train I   In
Fail I   Out
Fail_Count I X  
Fixture.Score* FP X Out
Horizontal_Offset FP   In
Include_In_Job_Pass I   In
Model A X  
Model_Type I   In
Pass I   Out
Pass_Count I X  
Result S X  
Rotation_Tolerance I X In
Scale_Tolerance I X In
Search A X  
Status I X  
Timeout I X In
Tool_Enabled I X In
Tool_Enabled_Status I X  
Train A X  
Vertical_Offset FP   In
*In-Sight 2000-130/130C vision sensors only

In-Sight 2000 Series 23X Vision Sensors (23M, 230)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Accept_Threshold I X In/Out
Accuracy I X In/Out
Description S X In/Out
Error_Count I X Out
Execution_Time FP X Out
External_Train I   In/Out
Fail I   Out
Fail_Count I X Out
Fixture1-9.Angle1,2 FP X Out
Fixture1-9.Score1,2 FP X Out
Fixture1-9.X1,2 FP X Out
Fixture1-9.Y1,2 FP X Out
Fixture.Angle FP X Out
Fixture.Score FP X Out
Fixture.X FP X Out
Fixture.Y FP X Out
Horizontal_Offset FP X In/Out
Include_In_Job_Pass I X In/Out
Model A X  
Model_Type I X In/Out
Number_Found1 I X  
Number_To_Find1 I X In/Out
Pass I   Out
Pass_Count I X Out
Patterns S X Out
Result S X Out
Rotation_Tolerance I X In/Out
Scale_Tolerance I X In/Out
Search A X  
Sort_By1 I X In/Out
Status I X Out
Timeout I X In/Out
Tool_Enabled I X In/Out
Tool_Enabled_Status I X Out
Train A X  
Train_Input I X In/Out
Vertical_Offset FP X In/Out
 1 These tool properties are only available with the PatMax Patterns (1-10) Location Tool.

2 Fixture1-9 refers to the ten iterations of the Fixture outputs (i.e. Fixture1, Fixture2, Fixture 3, etc.) for the Patterns (1-10) Location Tool.

In-Sight Vision Systems

Symbolic Name Data Type OPC EasyView Input/Output Data
Accept_Threshold I X X In/Out
Accuracy I X X In/Out
Description S X X In/Out
Error_Count I X X Out
Execution_Time FP X X Out
External_Train I X   In/Out
Fail I X   Out
Fail_Count I X X Out
Fixture1-9.Angle1,2 FP X X Out
Fixture1-9.Score1,2 FP X X Out
Fixture1-9.X1,2 FP X X Out
Fixture1-9.Y1,2 FP X X Out
Fixture.Angle FP X X Out
Fixture.Score FP X X Out
Fixture.X FP X X Out
Fixture.Y FP X X Out
Horizontal_Offset FP X X In/Out
Include_In_Job_Pass I X X In/Out
Model A X X  
Model_Type I X X In/Out
Number_Found1 I X X  
Number_To_Find1 I X X In/Out
Pass I X   Out
Pass_Count I X X Out
Patterns S X X Out
Result S X X Out
Rotation_Tolerance I X X In/Out
Scale_Tolerance I X X In/Out
Search A X X  
Sort_By1 I X X In/Out
Status I X X Out
Timeout I X X In/Out
Tool_Enabled I X X In/Out
Tool_Enabled_Status I X X Out
Train A X X  
Train_Input I X X In/Out
Vertical_Offset FP X X In/Out
 1 These tool properties are only available with the PatMax Patterns (1-10) Location Tool.

2 Fixture1-9 refers to the ten iterations of the Fixture outputs (i.e. Fixture1, Fixture2, Fixture 3, etc.) for the Patterns (1-10) Location Tool.