Using the Blobs Counting Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

In-Sight 2000 Series 23X Vision Sensors (23M, 230)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Blob_Color I X In/Out
Blob_Threshold I X In/Out
Boundary I X In/Out
Description S X In/Out
Include_In_Job_Pass I X In/Out
Invert I X In/Out
Maximum I X In/Out
Maximum_Area FP X In/Out
Minimum I X In/Out
Minimum_Area FP X In/Out
Threshold_Mode I X In/Out
Tool_Enabled I X In/Out
Blob_Count FP X Out
Error_Count FP X Out
Execution_Time FP X Out
Fail FP   Out
Fail_Count FP X Out
Pass FP   Out
Pass_Count FP X Out
Status FP X Out
Tool_Enabled_Status FP X Out
Composite_Region A X  

In-Sight Vision Systems

Symbolic Name Data Type OPC EasyView Input/Output Data
Blob_Color I X X In/Out
Blob_Threshold I X X In/Out
Boundary I X X In/Out
Description S X X In/Out
Include_In_Job_Pass I X X In/Out
Invert I X X In/Out
Maximum I X X In/Out
Maximum_Area FP X X In/Out
Minimum I X X In/Out
Minimum_Area FP X X In/Out
Threshold_Mode I X X In/Out
Tool_Enabled I X X In/Out
Blob_Count FP X X Out
Error_Count FP X X Out
Execution_Time FP X X Out
Fail FP X   Out
Fail_Count FP X X Out
Pass FP X   Out
Pass_Count FP X X Out
Status FP X X Out
Tool_Enabled_Status FP X X Out
Composite_Region A   X