Using the Edges Counting Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

In-Sight 2000 Series 1XX Vision Sensors (110, 120, 130)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Angle_Range I   In
Description S X In
Edge_Contrast I   In
Edge_Count I X Out
Edge_Transition I   In
Edge_Width I   In
Execution_Time FP X  
Fail I   Out
Fail_Count I X  
Include_In_Job_Pass I   In
Invert I   In
Maximum I   In
Minimum I   In
Pass I   Out
Pass_Count I X  
Status I X  
Tool_Enabled I X In
Tool_Enabled_Status I X  

In-Sight 2000 Series 23X Vision Sensors (23M, 230)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Angle_Range I X In/Out
Description S X In/Out
Edge_Contrast I X In/Out
Edge_Transition I X In/Out
Include_In_Job_Pass I X In/Out
Invert I X In/Out
Maximum I X In/Out
Minimum I X In/Out
Tool_Enabled I X In/Out
Edge_Count I X Out
Edges S X Out
Error_Count I X Out
Fail FP   Out
Fail_Count FP X Out
Pass FP   Out
Pass_Count FP X Out
Status FP X Out
Tool_Enabled_Status FP X Out
Region A X  

In-Sight Vision Systems

Symbolic Name Data Type OPC EasyView Input/Output Data
Angle_Range I X X In/Out
Description S X X In/Out
Edge_Contrast I X X In/Out
Edge_Transition I X X In/Out
Include_In_Job_Pass I X X In/Out
Invert I X X In/Out
Maximum I X X In/Out
Minimum I X X In/Out
Tool_Enabled I X X In/Out
Edge_Count I X X Out
Edges S X X Out
Error_Count I X X Out
Fail FP X   Out
Fail_Count FP X X Out
Pass FP X   Out
Pass_Count FP X X Out
Status FP X X Out
Tool_Enabled_Status FP X X Out
Region A X X