Using the Edge Width Defect Detection Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

Symbolic Name Data Type OPC EasyView Input/Output Data
Area_Enabled I X X In/Out
Caliper_Index I X X In/Out
Caliper_Size I X X In/Out
Caliper_Spacing I X X In/Out
Contrast_Upper_Bound I X X In/Out
Description S X X In/Out
Edge_Width I X X In/Out
Edge0_Transition I X X In/Out
Edge1_Transition I X X In/Out
Find_Edge_Direction I X X In/Out
Find_Gaps I X X In/Out
Ignore_End_Gaps I X X In/Out
Include_In_Job_Pass I X X In/Out
Max_Area FP X X In/Out
Max_Size FP X X In/Out
Max_Width FP X X In/Out
Maximum_Gap FP X X In/Out
Min_Area FP X X In/Out
Min_Size FP X X In/Out
Min_Width FP X X In/Out
Minimum_Contrast I X X In/Out
Minimum_Gap FP X X In/Out
Pair_Size I X X In/Out
Region_Type I X X In/Out
Rule_First_Edge I X X In/Out
Rule_Pair_Size I X X In/Out
Rule_Strongest_Edge I X X In/Out
Score_Threshold I X X In/Out
Show_All_Calipers I X X In/Out
Size_Enabled I X X In/Out
Tool_Enabled I X X In/Out
Caliper_Count FP X X Out
Defects FP X X Out
Error_Count FP X X Out
Execution_Time FP X X Out
Fail FP X   Out
Fail_Count FP X X Out
Gaps FP X X Out
InspectEdgeWidth S X X Out
Maximum_Width FP X X Out
Minimum_Width FP X X Out
Pass FP X   Out
Pass_Count FP X X Out
Result S X X Out
Status FP X X Out
Tool_Enabled_Status FP X X Out
Total_Flaws FP X X Out
Masked_Region A X X  
Polyline_Path A X X