Using the Surface Flaw Detection Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

Symbolic Name Data Type OPC EasyView Input/Output Data
Automatic_Smoothing I X X In/Out
Composite_Region A   X  
Cumulative_Flaw_Size FP X X In/Out
Description S X X In/Out
Detection_Axis I X X In/Out
Detection_Size I X X In/Out
Display_Image I X X In/Out
Enable_Mask I X X In/Out
Erode_Mask_Count I X X In/Out
Error_Count I X X Out
Execution_Time FP X X Out
Fail I X    
Fail_Count I X X Out
Detection_Type I X X In/Out
Include_In_Job_Pass I X X In/Out
Invert I X X In/Out
Mask_Display_Image I X X In/Out
Mask_Method I X X In/Out
Mask_Smoothing_Factor I X X In/Out
Maximum_Flaw_Area FP X X In/Out
Maximum_Hole_Fill_Size I X X In/Out
Median_Kernel_Size I X X In/Out
Minimum_Contrast I X X In/Out
Minimum_Edge_Contrast I X X In/Out
Minimum_Flaw_Area FP X X In/Out
Minimum_Segment_Size I X X In/Out
Pass I X    
Pass_Count I X X Out
Sampling_Factor I X X In/Out
Smoothing_Factor I X X In/Out
Status I X X Out
Timeout I X X In/Out
Tool_Enabled I X X In/Out
Tool_Enabled_Status I X X Out
Total_Flaws S X X Out
Train_Mask A   X