Using the Color to Binary Image Filter Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

Note: When a color tool is added, the Name of the defined Color Library(s) will automatically be displayed and their properties can be included as OPC, EasyView or Input/Output Data selections.
Symbolic Name Data Type OPC EasyView Input/Output Data
Color_Library I X X In/Out
Description S X X In/Out
External_Model_Enable_Apply I X X In/Out
Include_In_Job_Pass I X X In/Out
Model_Enable I X X In/Out
Model_Enable_Select I X X In/Out
Tool_Enabled I X X In/Out
Error_Count FP X X Out
Execution_Time FP X X Out
Fail FP X   Out
Fail_Count FP X X Out
Pass FP X   Out
Pass_Count FP X X Out
Status FP X X Out
Tool_Enabled_Status FP X X Out
Model_Enable_Apply A X X  
Region A X X  

ExtractColorLibrary_1-5 Properties

Symbolic Name Data Type OPC EasyView Input/Output Data
Train_Event A X X In/Out
Train_Model S X X In/Out
Train_Operation I X X In/Out
Train_Procedure I X X  
Train_Region A X X  

MatchColorLibrar_1-5 Properties

Symbolic Name Data Type OPC EasyView Input/Output Data
Darker_Limit FP X X In/Out
Lighter_Limit FP X X In/Out
Train_Color S X X In/Out
Train_Event A X X  
Train_Region A X X