Using the Statistics Math & Logic Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

In-Sight 2000 Series 23X Vision Sensors (23M, 230)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Count_When_Offline I X In/Out
Description S X In/Out
Display I X In/Out
External_Reset I   In/Out
Include_In_Job_Pass I X In/Out
Job_Load_Reset I X In/Out
Online_Reset I X In/Out
Tool_Enabled I X In/Out
Error_Count FP X Out
Execution_Time FP X Out
Fail FP   Out
Fail_Count FP X Out
Last_Value FP X Out
Maximum FP X Out
Mean FP X Out
Minimum FP X Out
Number_Of_Samples FP X Out
Pass FP   Out
Pass_Count FP X Out
Result FP X Out
Status FP X Out
Std_Dev FP X Out
Tool_Enabled_Status FP X Out
Reset A X  

In-Sight Vision Systems

Symbolic Name Data Type OPC EasyView Input/Output Data
Count_When_Offline I X X In/Out
Description S X X In/Out
Display I X X In/Out
External_Reset I X   In/Out
Include_In_Job_Pass I X X In/Out
Job_Load_Reset I X X In/Out
Online_Reset I X X In/Out
Tool_Enabled I X X In/Out
Error_Count FP X X Out
Execution_Time FP X X Out
Fail FP X   Out
Fail_Count FP X X Out
Last_Value FP X X Out
Maximum FP X X Out
Mean FP X X Out
Minimum FP X X Out
Number_Of_Samples FP X X Out
Pass FP X   Out
Pass_Count FP X X Out
Result FP X X Out
Status FP X X Out
Std_Dev FP X X Out
Tool_Enabled_Status FP X X Out
Reset A   X