Using the Angle Measurement Tool Input/Output Properties

The table below lists the tool's properties (Input parameters and Output results), listed by their symbolic name, data type and whether or not the property may be used for OPC communications, as EasyView items, and input and/or output data for external devices.

In-Sight 2000 Series 1XX Vision Sensors (110, 120, 130)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Angle FP X Out
Description S X In
Execution_Time FP X  
Fail I   Out
Fail_Count I X  
Include_In_Job_Pass I   In
Invert I   In
Maximum FP   In
Minimum FP   In
Pass I   Out
Pass_Count I X  
Status I X  
Tool_Enabled I X In
Tool_Enabled_Status I X  

In-Sight 2000 Series 23X Vision Sensors (23M, 230)

Note: OPC is not supported on the In-Sight 2000 series vision sensors.
Symbolic Name Data Type EasyView Input/Output Data
Description S X In/Out
Include_In_Job_Pass I X In/Out
Invert I X In/Out
Maximum FP X In/Out
Minimum FP X In/Out
Tool_Enabled I X In/Out
Angle FP X Out
Error_Count FP X Out
Execution_Time FP X Out
Fail FP   Out
Fail_Count FP X Out
Fixture.Angle FP X Out
Fixture.X FP X Out
Fixture.Y FP X Out
Pass FP   Out
Pass_Count FP X Out
Status FP X Out
Tool_Enabled_Status FP X Out

In-Sight Vision Systems

Symbolic Name Data Type OPC EasyView Input/Output Data
Description S X X In/Out
Include_In_Job_Pass I X X In/Out
Invert I X X In/Out
Maximum FP X X In/Out
Minimum FP X X In/Out
Tool_Enabled I X X In/Out
Angle FP X X Out
Error_Count FP X X Out
Execution_Time FP X X Out
Fail FP X   Out
Fail_Count FP X X Out
Fixture.Angle FP X X Out
Fixture.X FP X X Out
Fixture.Y FP X X Out
Pass FP X   Out
Pass_Count FP X X Out
Status FP X X Out
Tool_Enabled_Status FP X X Out